Home/Performance
Performance
Performance explorer.
Every value on this page comes from the published H&H performance tables: airflow and power at four pressures and three vacuum levels, by blower speed.
1,7002,400 RPM3,000
Airflow
Power required
Full table
HH860.
90 HP max · 1,000 CFM max. Open the HH860 datasheet.
| RPM | 12 PSIG | 16 PSIG | 18 PSIG | 20 PSIG | 12" Hg vac | 16" Hg vac | 17" Hg vac | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CFM | HP | CFM | HP | CFM | HP | CFM | HP | CFM | HP | CFM | HP | CFM | HP | |
| 1,800 | 482 | 33 | 465 | 42 | 450 | 50 | 440 | 55 | 498 | 17 | 469 | 21 | 445 | 23 |
| 1,900 | 517 | 35 | 500 | 44 | 485 | 52 | 475 | 58 | 533 | 18 | 503 | 22 | 480 | 25 |
| 2,000 | 552 | 37 | 535 | 46 | 519 | 55 | 510 | 61 | 568 | 18 | 538 | 23 | 515 | 26 |
| 2,100 | 587 | 39 | 569 | 49 | 554 | 58 | 544 | 64 | 602 | 19 | 573 | 24 | 550 | 27 |
| 2,200 | 621 | 41 | 604 | 51 | 589 | 61 | 579 | 68 | 637 | 20 | 607 | 25 | 584 | 28 |
| 2,300 | 656 | 43 | 639 | 53 | 623 | 64 | 614 | 71 | 672 | 21 | 642 | 26 | 619 | 30 |
| 2,400 | 691 | 45 | 674 | 56 | 658 | 66 | 648 | 74 | 706 | 22 | 677 | 27 | 654 | 31 |
| 2,500 | 725 | 47 | 708 | 58 | 693 | 69 | 683 | 77 | 741 | 23 | 712 | 29 | 688 | 32 |
| 2,600 | 760 | 48 | 743 | 60 | 727 | 72 | 718 | 80 | 776 | 24 | 746 | 30 | 723 | 34 |
| 2,700 | 795 | 50 | 778 | 63 | 762 | 75 | 753 | 83 | 811 | 25 | 781 | 31 | 758 | 35 |
| 2,800 | 829 | 52 | 812 | 65 | 797 | 78 | 787 | 86 | 845 | 26 | 816 | 32 | 792 | 36 |
| 2,900 | 864 | 54 | 847 | 67 | 832 | 81 | 822 | 89 | 880 | 27 | 850 | 33 | 827 | 38 |
| 3,000 | 899 | 56 | 882 | 70 | 866 | 83 | 857 | 90 | 915 | 28 | 885 | 34 | 862 | 39 |
Full table
HH1060.
115 HP max · 1,200 CFM max. Open the HH1060 datasheet.
| RPM | 12 PSIG | 16 PSIG | 18 PSIG | 19 PSIG | 12" Hg vac | 16" Hg vac | 17" Hg vac | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CFM | HP | CFM | HP | CFM | HP | CFM | HP | CFM | HP | CFM | HP | CFM | HP | |
| 1,700 | 590 | 42 | 556 | 55 | 543 | 62 | 536 | 66 | 605 | 22 | 565 | 27 | 534 | 31 |
| 1,800 | 635 | 44 | 602 | 59 | 589 | 66 | 582 | 69 | 651 | 22 | 611 | 27 | 580 | 31 |
| 1,900 | 680 | 47 | 648 | 62 | 635 | 70 | 628 | 73 | 697 | 23 | 657 | 29 | 626 | 32 |
| 2,000 | 728 | 49 | 694 | 65 | 681 | 73 | 674 | 77 | 743 | 24 | 703 | 30 | 672 | 35 |
| 2,100 | 773 | 52 | 740 | 69 | 727 | 77 | 720 | 81 | 789 | 25 | 749 | 32 | 718 | 36 |
| 2,200 | 819 | 54 | 786 | 72 | 773 | 81 | 766 | 85 | 835 | 27 | 795 | 33 | 764 | 38 |
| 2,300 | 866 | 57 | 832 | 75 | 819 | 84 | 812 | 89 | 881 | 28 | 841 | 35 | 810 | 39 |
| 2,400 | 912 | 59 | 878 | 79 | 865 | 88 | 858 | 93 | 927 | 29 | 887 | 36 | 856 | 41 |
| 2,500 | 960 | 61 | 924 | 82 | 911 | 92 | 904 | 97 | 973 | 30 | 933 | 38 | 902 | 43 |
| 2,600 | 1,009 | 65 | 970 | 85 | 957 | 96 | 950 | 101 | 1,019 | 32 | 979 | 39 | 948 | 44 |
| 2,700 | 1,047 | 67 | 1,016 | 89 | 1,003 | 100 | 996 | 105 | 1,065 | 33 | 1,025 | 41 | 994 | 46 |
| 2,800 | 1,093 | 70 | 1,062 | 92 | 1,049 | 103 | 1,042 | 109 | 1,111 | 34 | 1,071 | 42 | 1,040 | 48 |
| 2,900 | 1,139 | 72 | 1,108 | 96 | 1,095 | 107 | 1,088 | 113 | 1,157 | 35 | 1,117 | 44 | 1,086 | 50 |
| 3,000 | 1,185 | 75 | 1,154 | 99 | 1,141 | 111 | 1,134 | 115 | 1,203 | 36 | 1,163 | 45 | 1,132 | 51 |
Not sure which model fits?
Send your operating pressure, blower speed and current blower model. We recommend the right H&H blower.